Containment Ventilation During Accident Conditions

Overview

During accident conditions, nuclear containment ventilation systems transition from normal operation to emergency modes designed to maintain containment integrity, remove decay heat, control combustible gases, and protect the environment from radioactive releases.

Containment Isolation on Accident Signal

Automatic Isolation Logic

Containment isolation occurs within seconds of detecting accident conditions:

Isolation Signals:

  • High containment pressure (typically >3 psig)
  • High radiation levels in containment atmosphere
  • Safety injection actuation signal (SIAS)
  • Low reactor coolant system pressure
  • High steam line differential pressure

Isolation Valve Closure:

  • Phase A isolation: Non-essential penetrations close immediately
  • Phase B isolation: Essential systems isolated on high containment pressure
  • Redundant isolation valves in series on each penetration
  • Valve closure time: 4-10 seconds typical
  • Power sources: Safety-related DC and AC systems

Penetration Classification

Penetration TypeIsolation MethodClosure TimeRedundancy
Purge supply/exhaustMotor-operated valves5 secondsTwo in series
Equipment hatchManual bolted closurePre-accidentSingle barrier
Personnel airlockInterlocked doorsMaintainedDouble door
Piping <2 inchesCheck valvesImmediateSingle/double
ElectricalSealed penetrationContinuousPressure boundary
InstrumentationIsolation valves10 secondsTwo in series

Post-Accident Hydrogen Control

Hydrogen Generation Mechanisms

During core damage accidents, metal-water reactions generate hydrogen:

$$Q_{H_2} = n_{Zr} \times \Delta H_{rxn}$$

Where:

  • $Q_{H_2}$ = energy released from hydrogen generation (kJ)
  • $n_{Zr}$ = moles of zirconium oxidized
  • $\Delta H_{rxn}$ = reaction enthalpy (586 kJ/mol for Zr + 2H₂O)

Zirconium-Water Reaction: $$Zr + 2H_2O \rightarrow ZrO_2 + 2H_2 + \text{energy}$$

Hydrogen Control Systems

Passive Autocatalytic Recombiners (PARs):

  • Catalytic surface promotes H₂ + ½O₂ → H₂O at ambient temperature
  • No power required, self-initiating above 1-2% H₂
  • Heat release: approximately 242 kJ/mol H₂ recombined
  • Distribution: 50-100+ units throughout containment
  • Design capacity: prevents >10% H₂ concentration

Deliberate Ignition Systems:

  • Glow plug igniters activate at preset H₂ concentrations
  • Controlled burns prevent deflagration/detonation
  • Typical activation: 8-10% H₂ by volume
  • Power requirements: safety-related batteries

Mixing Systems:

  • Containment air recirculation fans
  • Prevent stratification and local accumulation
  • Flow rates: 10,000-50,000 cfm per fan
  • Redundant fans on separate power divisions

Containment Cooling Methods

Post-Accident Heat Removal

Total decay heat following reactor shutdown:

$$Q_{decay}(t) = Q_0 \times \left(0.066 \times \frac{t^{-0.2} - (t+T)^{-0.2}}{T^{0.2}}\right)$$

Where:

  • $Q_{decay}(t)$ = decay heat at time t (MW)
  • $Q_0$ = reactor thermal power before shutdown (MW)
  • $t$ = time after shutdown (seconds)
  • $T$ = reactor operating time before shutdown (seconds)

Cooling System Configurations

Containment Spray Systems:

  • Spray flow rates: 2,000-4,000 gpm per train
  • Spray coverage: >95% of containment volume
  • Droplet size: 500-1,000 microns for optimal heat/mass transfer
  • Spray temperature: initially ambient, increases to 150-200°F
  • Chemical addition: sodium hydroxide or trisodium phosphate for iodine removal

Heat removal by spray:

$$Q_{spray} = \dot{m}{spray} \times c_p \times (T{vapor} - T_{spray,in})$$

Where:

  • $Q_{spray}$ = heat removal rate (Btu/hr)
  • $\dot{m}_{spray}$ = spray mass flow rate (lb/hr)
  • $c_p$ = specific heat of water (1.0 Btu/lb-°F)
  • $T_{vapor}$ = containment atmosphere temperature (°F)
  • $T_{spray,in}$ = spray inlet temperature (°F)

Containment Fan Coolers:

  • Redundant units: 2-4 per containment
  • Cooling capacity: 20-50 million Btu/hr per unit
  • Airflow: 40,000-70,000 cfm per fan
  • Cooling water source: service water or component cooling
  • Operates during small breaks where containment remains subcooled

Ice Condenser Systems (PWR-specific):

  • Ice mass: 2-3 million pounds
  • Heat absorption: approximately 144 Btu/lb (latent heat of fusion)
  • Passive operation initiated by pressure differential
  • Door opening pressure: 1-2 psid

Filtered Venting Systems

Purpose and Design

Filtered containment venting systems prevent overpressure failure during extended severe accidents while minimizing radioactive releases.

Vent Activation Criteria:

  • Containment pressure approaching design limit (45-60 psig)
  • Alternative AC power unavailable
  • Containment cooling systems inoperable
  • Core damage confirmed or highly probable

Filter Technologies:

Filter TypeRemoval EfficiencyTarget SpeciesConfiguration
Metal fiber pre-filter>99% for particles >1 μmLarge particulatesUpstream
Venturi scrubber95-99.9% for aerosolsCesium, iodine compoundsPrimary
Metal fiber HEPA>99.9% for particles >0.3 μmFine aerosolsSecondary
Molecular sieve>95% for elemental iodineI₂, organic iodidesTertiary

Decontamination Factors:

  • Overall DF for aerosols: 1,000-10,000
  • Elemental iodine: 100-1,000
  • Noble gases: 1 (no retention)

Severe Accident Considerations

Containment Challenge Mechanisms

Overpressure Threats:

  • Steam generation from core-concrete interaction
  • Non-condensible gas accumulation (H₂, CO, CO₂)
  • Loss of containment heat removal
  • Design pressure typically 45-60 psig; failure predicted at 90-150 psig

Thermal Loads:

  • Direct containment heating from high-pressure melt ejection
  • Hydrogen combustion
  • Core debris on containment floor

Basemat Penetration:

  • Molten corium-concrete interaction (MCCI)
  • Attack rate: 2-6 inches/hour depending on concrete type
  • Gas generation exacerbates pressure challenge

Mitigation Strategies

Cavity Flooding:

  • Deliberate flooding of reactor cavity with 3-6 feet of water
  • Stabilizes core debris, prevents basemat penetration
  • Steam generation manageable with spray systems

Hydrogen Ignition Management:

  • Controlled burns preferable to delayed deflagration
  • Inerted containments (BWR with nitrogen) eliminate combustion risk

Recovery Ventilation Sequences

Post-Accident Atmosphere Restoration

graph TD
    A[Accident Conditions] --> B[Containment Isolated]
    B --> C{Core Damage?}
    C -->|No| D[Monitor H2, Radiation]
    C -->|Yes| E[Severe Accident Management]
    D --> F{Pressure Reduced?}
    F -->|Yes| G[Radiation Levels Acceptable?]
    F -->|No| H[Continue Spray/Cooling]
    G -->|Yes| I[Begin Purge Planning]
    G -->|No| J[Wait for Decay]
    I --> K[Establish Filtered Exhaust]
    K --> L[Gradual Pressure Reduction]
    L --> M[Sample Atmosphere]
    M --> N{Safe to Continue?}
    N -->|Yes| O[Controlled Purge to Stack]
    N -->|No| P[Re-isolate]
    O --> Q[Personnel Entry Possible]
    E --> R[Filtered Venting if Required]
    R --> S[Long-term Cooling Established]
    S --> J
    H --> F
    J --> G
    P --> J

Purge System Restoration

Prerequisites for Purge:

  • Containment pressure <1 psig above atmospheric
  • Hydrogen concentration <2% by volume
  • Radiation levels permit HEPA/charcoal filter operation
  • Decay heat removal established and stable
  • Emergency response organization approval

Purge Sequence:

  1. System alignment (0-2 hours):

    • Verify filter train integrity and pressure drop
    • Establish negative containment pressure capability
    • Confirm stack monitoring operational
  2. Initial venting (2-24 hours):

    • Flow rate: 100-500 cfm initially
    • Maintain negative pressure: -0.1 to -0.5 inches w.c.
    • Continuous stack and containment atmosphere monitoring
  3. Full purge operation (1-7 days):

    • Increase flow to design rates: 2,000-10,000 cfm
    • Multiple volume changes to reduce contamination
    • Target: <1% of initial airborne activity before entry

Containment Parameters During Recovery:

ParameterAccident PeakStart PurgeEntry Permitted
Pressure (psig)45-60<1.0<0.1
Temperature (°F)250-350<150<120
Humidity (%)100<95<80
H₂ concentration (%)0-10+<2.0<0.5
Radiation level (R/hr)>1,000<100<0.1
Airborne contaminationHighModerateLow

Summary

Containment ventilation during accident conditions prioritizes public safety through automatic isolation, decay heat removal, combustible gas control, and filtered release pathways. Recovery ventilation enables eventual containment access while maintaining radiological protection. Design basis and severe accident management strategies ensure containment integrity across the full spectrum of postulated events.