HVAC Systems Encyclopedia

A comprehensive encyclopedia of heating, ventilation, and air conditioning systems

Plate Freezers for Fish Processing

Contact Freezing Principles

Plate freezers utilize direct conduction heat transfer by sandwiching fish products between refrigerated metal plates. This contact freezing method achieves superior heat transfer rates compared to air blast systems due to the fundamental difference in thermal conductivity between metal and air.

The heat transfer coefficient for plate freezing ranges from 100-400 W/(m²·K), compared to 10-50 W/(m²·K) for air blast systems. This dramatic improvement stems from conductive heat transfer eliminating the convective boundary layer resistance that dominates air freezing.

Heat Transfer Mechanism

The overall heat transfer during plate freezing follows Fourier’s law of conduction:

$$Q = \frac{k \cdot A \cdot (T_p - T_f)}{x}$$

Where:

  • $Q$ = heat transfer rate (W)
  • $k$ = thermal conductivity of fish (1.2-1.8 W/(m·K) for unfrozen, 2.0-2.4 W/(m·K) for frozen)
  • $A$ = contact surface area (m²)
  • $T_p$ = plate surface temperature (°C)
  • $T_f$ = fish temperature (°C)
  • $x$ = product thickness (m)

The contact resistance between plate and product significantly impacts freezing efficiency. Hydraulic pressure systems (2-10 bar) minimize air gaps and improve contact conductance from 200 W/(m²·K) to 800 W/(m²·K).

graph TD
    A[Product Loading] --> B[Plate Closure]
    B --> C[Hydraulic Pressure Applied]
    C --> D[Refrigerant Flow Through Plates]
    D --> E[Heat Extraction via Conduction]
    E --> F{Core Temperature -18°C?}
    F -->|No| E
    F -->|Yes| G[Brief Defrost Release]
    G --> H[Product Ejection]
    H --> I[Next Batch Loading]

    style C fill:#e1f5ff
    style E fill:#ffe1e1
    style G fill:#fff4e1

Horizontal Plate Freezers

Horizontal plate freezers feature vertically-stacked refrigerated shelves with products loaded horizontally between plates. This configuration dominates land-based processing facilities due to ease of automation and high throughput capacity.

Design Characteristics:

ParameterTypical RangeNotes
Plate spacing50-150 mmAdjustable for product thickness
Number of plates12-40 shelvesDetermines batch capacity
Plate dimensions1.0 x 1.5 m to 1.5 x 3.0 mStandard sizes
RefrigerantNH₃, R-404A, R-507AAmmonia preferred for efficiency
Evaporation temperature-40°C to -45°CLower than air blast systems
Hydraulic pressure3-7 barEnsures uniform contact
Freezing capacity1000-8000 kg/batchFacility dependent

Freezing Time Calculation

Plank’s equation provides freezing time estimation for plate freezers:

$$t_f = \frac{\rho L}{T_f - T_m} \left[\frac{Pa}{h} + \frac{Ra^2}{k}\right]$$

Where:

  • $t_f$ = freezing time (s)
  • $\rho$ = density (1040 kg/m³ for fish)
  • $L$ = latent heat of fusion (250-280 kJ/kg for fish)
  • $T_f$ = freezing medium temperature (°C)
  • $T_m$ = initial freezing point (-1 to -2°C for fish)
  • $P$ = dimensionless constant (0.5 for infinite plate)
  • $R$ = dimensionless constant (0.125 for infinite plate)
  • $a$ = half-thickness of product (m)
  • $h$ = surface heat transfer coefficient (W/(m²·K))
  • $k$ = thermal conductivity (W/(m·K))

For a 50 mm thick fish block at -40°C plate temperature:

$$t_f = \frac{1040 \times 270,000}{(-40) - (-1.5)} \left[\frac{0.5 \times 0.025}{300} + \frac{0.125 \times 0.025^2}{2.2}\right] \approx 2.1 \text{ hours}$$

Vertical Plate Freezers

Vertical plate freezers position plates vertically with products inserted between adjacent plates. This configuration predominates in at-sea processing due to space efficiency and stability in vessel motion.

Advantages for Marine Applications:

  • Space efficiency: Smaller footprint for vessel installation
  • Stability: Vertical orientation better handles ship motion
  • Drainage: Gravity-assisted removal of excess water/brine
  • Product quality: Reduced deformation under hydraulic pressure

Design considerations:

graph LR
    A[Vertical Plates] --> B[Fish Blocks Inserted]
    B --> C[Hydraulic Ram Closes Plates]
    C --> D[Refrigerant Circulation]
    D --> E[Freezing Process]
    E --> F[Plates Separate]
    F --> G[Frozen Blocks Drop to Conveyor]

    style D fill:#e1f5ff
    style E fill:#ffe1e1
FeatureHorizontalVertical
Floor spaceLargerCompact
LoadingManual or automatedTypically manual
Product ejectionLift-out requiredGravity-assisted
At-sea suitabilityPoorExcellent
ThroughputHigherModerate
Capital costHigherLower

Block Freezing Applications

Plate freezers excel at producing uniform frozen fish blocks for further processing. Standard block dimensions (400 x 200 x 50-100 mm) facilitate efficient storage, transport, and subsequent cutting operations.

Product Forms:

  1. Filleted blocks: Skinless, boneless fillets arranged uniformly
  2. Minced blocks: Mechanically separated fish for surimi production
  3. Interleaved blocks: Fillets separated by polyethylene sheets
  4. Whole small fish: Sardines, anchovies in block form

Quality factors:

The rapid freezing achieved by plate systems (cooling rate 5-20°C/hour through -1 to -5°C zone) produces small ice crystals (20-50 μm diameter) that minimize cellular damage. Air blast freezing produces larger crystals (50-150 μm) with greater drip loss upon thawing.

$$\text{Ice crystal size} \propto \frac{1}{\text{cooling rate}}$$

At-Sea Processing Systems

Factory trawlers utilize vertical plate freezers to process and freeze catch immediately, maximizing product quality. Typical installations include 4-12 vertical plate freezers with total capacity 30-80 tonnes per 24-hour period.

System integration:

flowchart TD
    A[Fish Catch] --> B[Filleting/Processing]
    B --> C[Weighing/Portioning]
    C --> D[Block Mold Filling]
    D --> E[Vertical Plate Freezer Loading]
    E --> F[Hydraulic Compression]
    F --> G[Freezing Cycle 2-4 hours]
    G --> H[Release and Ejection]
    H --> I[Glazing]
    I --> J[Packaging]
    J --> K[Cold Storage -25°C]

    style E fill:#e1f5ff
    style G fill:#ffe1e1
    style K fill:#e1ffe1

Marine considerations:

  • Refrigeration capacity: 500-2000 kW for full processing line
  • Power supply: Diesel generator sets with heat recovery
  • Seawater cooling: Condenser systems using ambient seawater
  • Stability systems: Gyroscopic mounts for freezer units
  • Corrosion protection: Stainless steel construction (316L grade)

Hydraulic Pressure Systems

Hydraulic rams apply uniform pressure across plate surfaces, crucial for achieving consistent thermal contact. Pressure must overcome product irregularities and flatten air pockets without crushing delicate fillets.

The contact conductance relationship follows:

$$h_c = C \cdot P^{0.6}$$

Where $h_c$ is contact conductance (W/(m²·K)), $P$ is applied pressure (Pa), and $C$ is an empirical constant dependent on surface roughness.

Pressure optimization:

Product TypeOptimal PressureRationale
Delicate fillets2-4 barPrevents crushing
Robust fillets4-7 barMaximizes contact
Minced blocks6-10 barCompacts material

Operational Efficiency

Plate freezer efficiency depends on minimizing non-productive time:

$$\text{Utilization} = \frac{t_f}{t_f + t_l + t_r}$$

Where:

  • $t_f$ = freezing time
  • $t_l$ = loading time (5-15 minutes)
  • $t_r$ = release/defrost time (2-5 minutes)

Achieving 85-90% utilization requires automated loading systems and optimized defrost cycles. Brief plate surface warming (-40°C to -5°C for 60-90 seconds) breaks ice bonds without significant refrigeration capacity waste.

Energy consumption: Plate freezers consume 40-80 kWh per tonne of frozen product, approximately 30% more efficient than equivalent air blast systems due to reduced freezing time and better insulation efficiency.

Quality Control Parameters

Critical monitoring points:

  • Plate surface temperature uniformity (±2°C across all plates)
  • Hydraulic pressure consistency (±0.3 bar variation)
  • Product core temperature at release (≤ -18°C per ASHRAE guidelines)
  • Contact time sufficiency (minimum 2 hours for 50mm blocks)
  • Defrost cycle timing (excessive warming degrades efficiency)

ASHRAE Refrigeration Handbook Chapter 29 provides detailed guidance on plate freezer design and operation for fishery products, emphasizing the importance of maintaining product quality through controlled freezing rates and proper temperature management.


References:

  • ASHRAE Refrigeration Handbook, Chapter 29: Fishery Products
  • ASHRAE Handbook - Fundamentals, Chapter 10: Heat Transfer